UV-C and plasma technology for clean air on the ward
Air quality is of central importance in hospitals: Patients with weakened immune systems, medical staff and sensitive equipment often share cramped rooms with high air circulation. Conventional ventilation systems are often not sufficiently germ-free – the risk of nosocomial infections and odor pollution increases.
oxytec systems with UV-C and plasma technology ensure hygienic room air, significantly reduce the germ load and increase protection on the ward – without any ongoing operational restrictions.
What would you like to know?
Simply put your question to our AI. They will answer you individually:
Typical problem areas in hospital rooms
| Problem zone | Typical stresses | Consequences |
|---|---|---|
| Patient rooms | Viruses, germs, bioaerosols, odors | Risk of infection for patients and staff |
| Corridors and airlocks | Droplet aerosols, contaminated circulating air | Spread of germs across wards |
| Nurses’ stations | Confined spaces, high frequency of people | Risk of cross-contamination |
| Ventilation systems without disinfection | Re-contamination, mold, odor | Hygienic deficiencies and odor problems |
Why oxytec for hygienic hospital air?
UV-C inactivates germs in the room air – permanently and safely
Plasma technology reduces odors and bioaerosols
Solutions for continuous operation in occupied rooms
VDI-compliant, validated, low-maintenance
Suitable for new builds and retrofitting
Legal requirements
VDI 6022 – Hygiene requirements for air conditioning systems
Defines technical and hygienic standards
Cleaning, inspection and maintenance mandatory
IfSG – Infection Protection Act
Prevention of hospital infections through technical measures
Room air is considered a relevant transmission path
Hygiene begins in the air. Safety for patients, relief for staff.
o xytec – air purification for modern hospital environments.
Get advice now – together we can make your air safe.
Technical solutions from oxytec
UV-C circulating air disinfection
- Reduces germ load in occupied wards
- No UV emission into the room – safe for patients
- Compact devices for wall or ceiling mounting
Plasma and UV ozone technology
- Decomposes organic odors (e.g. wound care, disinfectants)
- Significantly reduces the bioaerosol concentration
- Particularly suitable for isolation rooms and intensive care units
Integration in ventilation technology
- Retrofittable slide-in modules for air conditioning systems
- Hygiene standard according to VDI 6022
- Low maintenance – high operational reliability
Typical areas of application
- Single and multi-bed patient rooms
- Intensive care units and isolation areas
- Ward corridors, lounges and quiet rooms
- Diagnostic and procedure areas with patient contact
- Sanitary areas with ventilation to the ward
Your advantages with oxytec in hospital areas
Visible hygiene measures – boosting patient confidence
Reduction of infection risks and germ load
Neutralization of unpleasant odours without fragrances
Validated technology, documentable for QM systems
Flexible integration even during ongoing hospital operations
FAQ – häufige Fragen
How is the air in hospital areas effectively sanitized?
oxytec relies on a combination of UV-C and plasma technology:
- UV-C reliably deactivates viruses, bacteria and fungal spores
- Plasma reduces bioaerosols and breaks down odors
- Cleaning is continuous, residue-free and chemical-free
This keeps the room air sustainably germ-free even under real conditions.
Can it also be used in occupied wards?
Yes – our systems are designed for continuous operation in occupied rooms:
- UV-C components are light-proof encapsulated, no danger for patients
- Plasma units work with controlled ozone reaction and safe degradation
- The technology is safe for staff, patients and medical devices
How is the technology integrated into existing hospital areas?
Our solutions are modular and retrofittable, e.g:
- Wall and ceiling units for patient rooms or airlocks
- Built-in units for central air conditioning systems
- Compact recirculation units for functional rooms
Installation is often possible without interfering with the building fabric.
What distinguishes oxytec from conventional air filters?
Our systems do not work passively, but actively:
- UV-C destroys germs, instead of just filtering them out
- Plasma breaks down odor molecules and organic pollutants
- No use of fragrances – suitable for sensitive patients
How much maintenance is required in everyday clinical practice?
Maintenance is predictable and low:
- UV-C tubes: Replacement every 8,000-12,000 operating hours
- Plasma elements: depending on model maintenance-free or plug-in modules
- Filters (if used): typically 1-2 services per year
A service contract or instruction from the building services team is possible.
What standards and hygiene requirements does oxytec meet?
Our systems are:
- VDI 6022-compliant (air quality in HVAC systems)
- DIN EN 60335-compliant (electrical safety)
- Microbiologically validated by independent laboratories
- Suitable for use in ISO-certified facilities
Can larger hospital areas also be equipped with them?
Yes – we are planning scalable solutions:
- Individual systems per room or Central solutions for entire wards
- Integration into existing air ducting systems
- Also suitable for temporary isolation areas or emergency rooms
Are there funding programs for air purification in hospitals?
Yes – subsidies are available for investments in hygiene and infection protection:
- Programs at federal or state level
- Support from KfW, BAFA or special clinic subsidies
- We provide all technical documents for the application process
We would be happy to advise you individually on the eligibility of your planned measure.